Nuclear Medicine Toolkit — About this tool
A comprehensive, browser-based clinical calculator suite for nuclear medicine departments. All computations run locally — no data is transmitted or stored externally.
▸ Dose Preparation Syringe pre-calibration computes the activity to draw at preparation time to deliver a precise prescribed dose at injection time, fully accounting for physical decay (Asyringe = Adesired × e+λ·Δt). Certificate decay calculates residual activity from the vial calibration certificate at any target date and time. Volume & dilution derives draw volumes and final concentrations from stock solutions. The decay curve is expressed in real clock time from preparation to end of study, with a marker at administration time.
▸ Patient Dosimetry Weight-based and pediatric (EANM dosage card method) activity prescription with configurable maximum caps. Effective half-life calculated from physical and biological components: Teff = Tphys·Tbiol / (Tphys+Tbiol). Patient residual activity over time and time-to-discharge threshold estimation.
▸ Radiation Protection Point-source dose rate via inverse square law (H = Γ·A/d²) with isotope-specific Γ constants. Shielding thickness calculator in lead and concrete (HVL/TVL). Time to reach regulatory release threshold. Breastfeeding interruption guidance per IAEA Safety Reports Series No. 40 & EANM guidelines.
▸ PET Quantification Standardised Uptake Value normalised to body weight (SUVbw), lean body mass (SUVlbm/SUL, Janmahasatian formula), and body surface area (SUVbsa, Du Bois). Dead time correction for paralysable and non-paralysable detector models. Radiochemical purity QC with configurable pass/fail threshold.
▸ Reference Tables Isotope-specific decay and pre-calibration correction factors, half-life comparison chart, and physical data (T½, gamma constant Γ, HVL in Pb and concrete) for 12 clinically used radionuclides: ¹&sup8;F, &sup9;&sup9;¹³Tc, ¹²³I, ¹³¹I, &sup6;&sup7;Ga, ¹¹¹In, ²&sup0;¹Tl, &sup6;&sup8;Ga, &sup8;²Rb, &sup8;&sup9;Sr, ¹&sup7;&sup7;Lu, ²²³Ra.
⚠ For professional use only. Always verify results against institutional protocols and current regulatory guidelines. The authors disclaim any liability for clinical decisions based solely on this tool.
▸ Dose Preparation Syringe pre-calibration computes the activity to draw at preparation time to deliver a precise prescribed dose at injection time, fully accounting for physical decay (Asyringe = Adesired × e+λ·Δt). Certificate decay calculates residual activity from the vial calibration certificate at any target date and time. Volume & dilution derives draw volumes and final concentrations from stock solutions. The decay curve is expressed in real clock time from preparation to end of study, with a marker at administration time.
▸ Patient Dosimetry Weight-based and pediatric (EANM dosage card method) activity prescription with configurable maximum caps. Effective half-life calculated from physical and biological components: Teff = Tphys·Tbiol / (Tphys+Tbiol). Patient residual activity over time and time-to-discharge threshold estimation.
▸ Radiation Protection Point-source dose rate via inverse square law (H = Γ·A/d²) with isotope-specific Γ constants. Shielding thickness calculator in lead and concrete (HVL/TVL). Time to reach regulatory release threshold. Breastfeeding interruption guidance per IAEA Safety Reports Series No. 40 & EANM guidelines.
▸ PET Quantification Standardised Uptake Value normalised to body weight (SUVbw), lean body mass (SUVlbm/SUL, Janmahasatian formula), and body surface area (SUVbsa, Du Bois). Dead time correction for paralysable and non-paralysable detector models. Radiochemical purity QC with configurable pass/fail threshold.
▸ Reference Tables Isotope-specific decay and pre-calibration correction factors, half-life comparison chart, and physical data (T½, gamma constant Γ, HVL in Pb and concrete) for 12 clinically used radionuclides: ¹&sup8;F, &sup9;&sup9;¹³Tc, ¹²³I, ¹³¹I, &sup6;&sup7;Ga, ¹¹¹In, ²&sup0;¹Tl, &sup6;&sup8;Ga, &sup8;²Rb, &sup8;&sup9;Sr, ¹&sup7;&sup7;Lu, ²²³Ra.
⚠ For professional use only. Always verify results against institutional protocols and current regulatory guidelines. The authors disclaim any liability for clinical decisions based solely on this tool.
Syringe Activity — Pre-calibration Calculator
Preparation time
When you fill the syringe
Administration time
When you inject the patient
Desired activity at injection (MBq)
Activity to draw at preparation time
— MBq
Decay from Calibration Certificate
Certificate activity (MBq)
Certificate date & time
Target date & time
Fill in all fields to calculate.
Volume & Dilution Calculator
Vial total activity (MBq)
Vial volume (mL)
Activity to draw (MBq)
Dilution
Stock concentration (MBq/mL)
Stock volume to use (mL)
Final volume (mL)
Decay Curve from Dose Preparation Time
Activity by Patient Weight
Reference dose/kg (MBq/kg)
¹⁸F-FDG ≈ 4 | ⁹⁹ᵐTc bone ≈ 11 | MAG3 ≈ 3.7
Patient weight (kg)
Maximum activity cap (MBq)
Pediatric Dose — EANM Dosage Card Method
Adult reference activity (MBq)
Patient weight (kg)
Minimum activity (MBq)
Effective Half-Life & Biological Clearance
Physical T½ (h) — auto from isotope
Biological T½ (h)
FDG brain ≈ 109h · ¹³¹I thyroid ≈ 80d (1920h)
Administered activity (MBq)
Residual Activity in Patient & Clearance Time
Administered activity (MBq)
Effective T½ (h)
← Auto-filled from Effective T½ above
Discharge threshold (MBq)
Typical: 25 MBq · Verify local protocol
Dose Rate at Distance — Point Source
Activity (MBq)
Distance (m)
Γ constant (μSv·m²·MBq⁻¹·h⁻¹)
Auto-set from isotope
H = Γ × A / d² · Doubling distance → dose rate ÷ 4
Shielding Calculator — HVL & TVL
Initial dose rate (μSv/h)
Target dose rate (μSv/h)
HVL in Pb (mm)
Auto-set from isotope
HVL in concrete (cm)
Time to Reach Release / Discharge Threshold
Initial activity (MBq)
Threshold activity (MBq)
IAEA: ~25 MBq · EU directive varies
Effective T½ (h)
Breastfeeding Interruption Guidance — IAEA / EANM
| Isotope | Application | Interruption |
|---|
Reference: IAEA Safety Reports Series No. 40 & EANM guidelines. Always verify with current institutional protocol.
SUV Calculator — Body Weight · Lean Mass · BSA
Tissue concentration (kBq/mL)
Injected activity (MBq)
Decay-corrected to scan time
Body weight (kg)
Height (cm)
SUV_lbm (SUL) recommended for serial studies and obese patients. LBM via Janmahasatian formula.
Dead Time Correction — Paralysable & Non-Paralysable
Measured count rate N_obs (cps)
Dead time τ (μs)
Model
Radiochemical Purity & Labelling Efficiency
Total activity measured (MBq)
Free / unbound activity (MBq)
Minimum acceptable purity (%)
Decay Factor Table
| Elapsed time | Residual (%) | Decay factor (×) | Pre-cal factor (×) | T½ elapsed |
|---|
Half-Life Comparison — All Isotopes
Isotope Reference Data
| Isotope | T½ | Decay | Γ (μSv·m²·MBq⁻¹·h⁻¹) | HVL Pb (mm) | HVL concrete (cm) | Clinical use |
|---|